Liquid Controls PULSE OUTPUT DEVICE (POD) / LC PULSE OUTPUT DEVICE (POD) /Flow Meter LC PULSE OUTPUT DEVICE (POD)

Liquid Controls PULSE OUTPUT DEVICE (POD) / LC PULSE OUTPUT DEVICE (POD) /Flow Meter LC PULSE OUTPUT DEVICE (POD)

STANDARD SPECIFICATIONS

Katalog : 
Liquid Controls PULSE OUTPUT DEVICE (POD)

Deskripsi

Jual Flow Meter LC, Liquid Controls Flow Meter, LC, Spesifikasi

Housing : Aluminum Alloy ADC12
Powder Coat : Corro-Coat PE 74-141 Polyester
Wetted Parts : 316 Stainless
Static Seals : Buna or PTFE
Voltage : 9 to 30 VDC; POD5 is 5 VDC
Current supply : 50 mA maximum
Output Signal
Resolution
: 100 pulses per channel
  per revolution, unscaled
Square Wave
: – Single channel output
    (channel A or channel B)
– Quadrature channel output
    channel A and channel B
Pulse Timing : Nominal 50% on and 50% off
Rise/Fall Time of Pulse : <5 μs
Operating
Temperature Range
: -40  to 176 °F (-40  to 80 °C)
Humidity Range : 0-100 %, noncondensing
Output
– Current sinking100 mA maximum in “ON” state
– V+ supply @ 2.2 KΩ in “OFF” state
– Optional Open Drain FET
  (Field Effect Transistor)
– FET rating (drain to source voltage)
  30 VDC maximum
Shock : 50 G’s for 10 ms
Vibration : 1 G at 10-150 Hz
Electromagnetic
Compatibility
(EMI, RFI, etc.)
• EU Directive 2004/108/EC (EMC)
• IEC 61000-4-2
• IEC 61000-4-3
• IEC 61000-4-5
• IEC 61000-4-6
• IEC 61000-4-17
• IEC 61000-4-29
• IEC 61000-6-3
• ISO 7637-2
Pulse Transmission
Distance
: Up to 5,000 feet (1,524 meters)