STANDARD SPECIFICATIONS

Katalog : 
LectroCount™ LCR-II PDF
EM100-10_(LCRII Install E3650-E3651 Series)_0

Deskripsi

Jual Flow Meter LC, Liquid Controls Flow Meter, LC, Spesifikasi

REPEATABLILITY: Capable of .03% of reading over entire range.

LINEARITY: Capable of ±0.10% or better over a 5:1 range from maximum nominal meter capacity.

LINEARITY: Capable of ±0.10% or better over a 10:1 range from maximum nominal meter capacity.

LINEARITY: Capable of ±0.15% or better over a 40:1 range from maximum nominal meter capacity.

Multi-point calibration for meters equipped with LectroCount™ Electronic Registration allows superior accuracy (linearity) as indicated above.

Power Requirements:

LectroCount® LCR-II: +9 – 28 VDC

Environmental:

Enclosure:  Class 1, Division 2, Group C&D design, NEMA 4X

Operating Temp Range:  -40° to 158°F (-40° to 70°C)

Approvals:

US Weights & Measures: LCR-II

Measurement Canada: LCR-II

Output:

RS232/485

Printer:

Epson, Okidata and Blaster Models

Electrical:

Power:  +9 to 28VDC, 3A maximum (including solenoid valves)

Inputs:

Temperature input: 4-Wire Platinum RTD

Pulse Inputs:  +5 to 28 volt peak to peak, open collector, single channel or quadrature